Sign In | Join Free | My himfr.com
Home > POCT Test Kit >

Diagnostic Rapid Blood Test Kits NT-ProBNP High Sensitivity In Whole Blood Plasma And Serum

WWHS Biotech.Inc(exclusive marketed by Dawin)
Contact Now
    Buy cheap Diagnostic Rapid Blood Test Kits NT-ProBNP High Sensitivity In Whole Blood Plasma And Serum from wholesalers
     
    Buy cheap Diagnostic Rapid Blood Test Kits NT-ProBNP High Sensitivity In Whole Blood Plasma And Serum from wholesalers
    • Buy cheap Diagnostic Rapid Blood Test Kits NT-ProBNP High Sensitivity In Whole Blood Plasma And Serum from wholesalers
    • Buy cheap Diagnostic Rapid Blood Test Kits NT-ProBNP High Sensitivity In Whole Blood Plasma And Serum from wholesalers
    • Buy cheap Diagnostic Rapid Blood Test Kits NT-ProBNP High Sensitivity In Whole Blood Plasma And Serum from wholesalers
    • Buy cheap Diagnostic Rapid Blood Test Kits NT-ProBNP High Sensitivity In Whole Blood Plasma And Serum from wholesalers

    Diagnostic Rapid Blood Test Kits NT-ProBNP High Sensitivity In Whole Blood Plasma And Serum

    Ask Lasest Price
    Brand Name : WWHS
    Model Number : NT-proBNP
    Certification : ISO13485
    Price : Negotiable
    Payment Terms : L/C, T/T
    Supply Ability : 30000 Kits per Week
    Delivery Time : 10 Days
    • Product Details
    • Company Profile

    Diagnostic Rapid Blood Test Kits NT-ProBNP High Sensitivity In Whole Blood Plasma And Serum

    【Product name】NT.pdf

    N-terminal prohormone of brain natriuretic peptide (NT-proBNP) Rapid Quantitative Test(Fluorescence immunoassay)


    Intended use

    This kit is used for quantitative determination of N-terminal prohormone of brain natriuretic peptide (NT-proBNP) in human whole blood and plasma,serum.


    【Inspection principle】

    The principle of immunofluorescence chromatography was applied to the kit. The NT-proBNP antigen in the sample was first bound with the conjugated compound of fluorescent labeled NT-proBNP monoclonal antibody, then moved and combined with another NT-proBNP monoclonal antibody fixed on the nitrocellulose membrane, and the double antibody sandwich complex was formed at the detection line of the cellulose nitrate membrane. The quantitative detection results were obtained by NIR-1000 dry fluoroimmunoassay analyser.


    【Main components】

    NameQuantityComponent
    Test card25It is composed of fluorescent pad (coated with fluorescent labeled N-terminal prohormone of brain natriuretic peptide (NT-proBNP) monoclonal mouse antibody), nitrocellulose membrane (coated with N-terminal prohormone of brain natriuretic peptide (NT-proBNP) monoclonal mouse antibody and Goat anti mouse IgG antibody), absorbent paper and backing
    Sample buffer25(300μL/tube)Phosphate buffer
    ID card1Record the standard curve information of this kit

    The components in different batches of kits cannot be used interchangeably.


    【Procedure】

    1. Before the test, please read the instructions completely. If the test card and sample are stored in cold storage, they should be balanced at room temperature (15-30)℃ for not less than 30min before use.

    2. Start NIR-1000 dry fluoroimmunoassay analyzer according to the instruction manual of the instrument, and carry out quality control verification according to the instruction manual of the instrument(Note: the reagent has been calibrated in advance, and the calibration curve parameters of each batch of reagent have been stored in the information card. The information card is inserted before use, so it is not necessary to calibrate again, and the test can be carried out only after the quality control is passed; Otherwise, the cause should be found out before testing.)

    3. Remove the test card from the aluminum foil bag and use it within 15 minutes.

    4. Place the test card on a clean horizontal table and mark it horizontally.

    5. Mix 100µL of patient sample with 300µL of sample diluent. Apply 100µL of diluted samples to the well of the test card.

    6. Insert the test card into NIR-1000 dry fluoroimmunoassay analyzer, press the [timing detection] key, automatically time for 10 minutes, automatically judge the test results, and display the quantitative results on the screen. Or insert the test card into the analyzer after timing for 10 minutes, and press the [real time detection] key, and the instrument will automatically interpret the test results.


    Reference interval

    Healthy subjects under 75 years old have assay values below 347pg/mL. Healthy subjects over 75 years old have assay values below 449pg/mL.


    Interpretation of results

    This reagent is only used for auxiliary detection. If the test results are abnormal, it should be reviewed in time and judged in combination with clinical symptoms.


    【Performance】

    1. Analysis sensitivity

    No more than 18pg/mL.

    2. Accuracy

    The relative deviation from the target value is within ±10%.

    3. Precision

    The within and between assay coefficient of variations are within 15%.

    4. Linear range

    Within the linear range (20-35000pg/mL), the linear correlation coefficient R≥0.990.



    Assay list     
    Cardiac     
    cat#.Product ItemSpecimenReaction TimeMeasure RangeClinical RangeIntended Use
    1cTnIWB/Serum/Plasma12min.0.1-40ng/ml<0.3ng/mlseveral heart diseases including myocardial infarction and heart failure.
    2MyoWB/Serum/Plasma12min.5-400ng/ml<58ng/mlacute myocardial infarction (AMI) in early stage.
    3CK-MBWB/Serum/Plasma12min.1-200ng/ml<5ng/mlacute myocardial infarction (AMI) in early stage.
    4NT-proBNPWB/Serum/Plasma10min.20-35000pg/mlUnder 75:0~347pg/mL,
    Over 75:0~449pg/mL
    heart failure .
    5D-DimerWB/Plasma10min.40-10000ng/ml<500ng/mldisseminated intravascular coagulation (DIC),deep vein thrombosis (DVT),pulmonary embolism (PE), myocardial infarction, cerebral infarction, etc.
    6cTnI+Myo+CKMBWB/Serum/Plasma12min.same with single itemsame with single itemTriple marker of myocardial infarction.
    7ST2WB/Serum/Plasma10min.10-400ng/ml<35ng/mlheart failure .
    8Lp-PLA2WB/Serum/Plasma10min.10-900ng/ml<175ng/mlRisk evaluation of ACS and atherosclerotic ischemic stroke patients.
    9S100-βWB/Serum/Plasma10min.0.05-10ng/ml<0.2ng/mlCerebral infarction, cerebral injury.

    Quality Diagnostic Rapid Blood Test Kits NT-ProBNP High Sensitivity In Whole Blood Plasma And Serum for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: WWHS Biotech.Inc(exclusive marketed by Dawin)
    *Subject:
    *Message:
    Characters Remaining: (0/3000)