Sign In | Join Free | My himfr.com
Home > Real Time PCR Kits >

WWHS IL-6 FIA Rapid Quantitative Test Kit The Quantitative Measurement

WWHS Biotech.Inc(exclusive marketed by Dawin)
Contact Now
    Buy cheap WWHS IL-6 FIA Rapid Quantitative Test Kit The Quantitative Measurement from wholesalers
     
    Buy cheap WWHS IL-6 FIA Rapid Quantitative Test Kit The Quantitative Measurement from wholesalers
    • Buy cheap WWHS IL-6 FIA Rapid Quantitative Test Kit The Quantitative Measurement from wholesalers
    • Buy cheap WWHS IL-6 FIA Rapid Quantitative Test Kit The Quantitative Measurement from wholesalers

    WWHS IL-6 FIA Rapid Quantitative Test Kit The Quantitative Measurement

    Ask Lasest Price
    Brand Name : WWHS
    Model Number : IL-6
    Certification : ISO 13485, CE
    Price : Negotiable
    Payment Terms : L/C, T/T
    Supply Ability : 20000 Kits per Week
    Delivery Time : 7 Days
    • Product Details
    • Company Profile

    WWHS IL-6 FIA Rapid Quantitative Test Kit The Quantitative Measurement

    【Product name】 19. IL-6.pdf

    Diagnostic Kit for Interleukin-6(Immunochromatographic assay)

    【Intended use】

    The kit is used for quantitative determination of Interleukin-6 (IL-6) in human whole blood, plasma and serum.

    【Test principle】

    The kit is a one-step chromatographic sandwich immunoassay designed for the quantitative measurement of IL-6. The IL-6 antigen in the sample was first bound with the conjugated compound of fluorescent labeled IL-6 monoclonal antibody, then moved and combined with another IL-6 monoclonal antibody fixed on the nitrocellulose membrane, and the double antibody sandwich complex was formed at the detection line of the cellulose nitrate membrane.

    【Applicable instrument】

    NIR-1000 dry fluoroimmunoassay analyser produced by WWHS Biotech. Inc.

    【Test procedure】

    1. Before the test, please read the instructions completely. If the test card and sample are stored in cold storage, they should be balanced at room temperature (15-30)℃ for not less than 30min before use.
    2. Start NIR-1000 dry fluoroimmunoassay analyser according to the instruction manual of the instrument, and carry out quality control verification according to the instruction manual of the instrument(Note: the reagent has been calibrated in advance, and the calibration curve parameters of each batch of reagent have been stored in the ID card. The test can be carried out only after the quality control is passed. Otherwise, the cause should be found out before testing.)
    3. Remove the test card from the aluminum foil bag and use it within 15 minutes.
    4. Place the test card on a clean horizontal table and mark it horizontally.
    5. Mix 100 µL of patient sample with 300µL of sample diluent. Apply 100 µL of diluted samples to the well of the test card.
    6. Insert the test card into NIR-1000 dry fluoroimmunoassay analyser, read and record the results at 10 minutes after addition of samples, then dispose of used test appropriately.

    【Note】

    1. The kit can be used for in vitro diagnosis only.

    2. Test card and buffer solution are single-use and they cannot be reused.

    3. Please check the integrity and validity of the kit package before use, and then open the package. When it is stored at low temperature, it should be restored to room temperature (15℃ ~ 30℃) before opening the package for use. The reagents with damaged inner package and beyond the validity period cannot be used.

    4. Take the test card out of the aluminum foil bag and carry out experiment in 15min. Do not place it in the air for a long time to avoid dampness.

    5. It is required to strictly comply with the requirements for sample collection and storage. If the sample is turbid, please centrifuge and precipitate it before use.

    6. The kit used should be disposed of as latent infective material, and all samples, reagents and latent contaminants should be disinfected and disposed of according to relevant local regulations.


    WWHS Assay list Inflammation    
    cat#.Product ItemSpecimenReaction TimeMeasure RangeClinical RangeIntended Use
    10CRP / hs-CRPWB/Serum/Plasma3min.0.5-200mg/LCRP<10mg/L,hs-CRP<1mg/Lnonspecficity inflammatory marker.
    11SAASerum5min.1-200mg/L<10mg/Linflammation&infection.
    12PCTWB/Serum/Plasma10min.0.2-100ng/ml<0.5ng/mlSepsis
    13CRP+SAAWB/Serum/Plasma5min.same with single itemsame with single iteminflammation&infection.
    14IL-6WB/Serum/Plasma10min.5-4000pg/ml10pg/mldiabetes,rheumatoid arthritis,etc

    Quality WWHS IL-6 FIA Rapid Quantitative Test Kit The Quantitative Measurement for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: WWHS Biotech.Inc(exclusive marketed by Dawin)
    *Subject:
    *Message:
    Characters Remaining: (0/3000)