Sign In | Join Free | My himfr.com
Home > Cardiac Testing Kit >

High Accuracy S100-β Rapid Quantitative Test Kit FIA POCT Assay High Sensitivity

WWHS Biotech.Inc(exclusive marketed by Dawin)
Contact Now
    Buy cheap High Accuracy S100-β Rapid Quantitative Test Kit FIA POCT Assay High Sensitivity from wholesalers
     
    Buy cheap High Accuracy S100-β Rapid Quantitative Test Kit FIA POCT Assay High Sensitivity from wholesalers
    • Buy cheap High Accuracy S100-β Rapid Quantitative Test Kit FIA POCT Assay High Sensitivity from wholesalers
    • Buy cheap High Accuracy S100-β Rapid Quantitative Test Kit FIA POCT Assay High Sensitivity from wholesalers

    High Accuracy S100-β Rapid Quantitative Test Kit FIA POCT Assay High Sensitivity

    Ask Lasest Price
    Brand Name : WWHS
    Model Number : S100-β
    Certification : ISO 13485, CE
    Price : Negotiable
    Payment Terms : L/C, T/T
    Supply Ability : 10000 Kits per Week
    Delivery Time : 7 Days
    • Product Details
    • Company Profile

    High Accuracy S100-β Rapid Quantitative Test Kit FIA POCT Assay High Sensitivity

    Product Name】 S100.pdf

    Diagnostic Kit for S100β protein(Immunochromatographic assay)


    【Applicable Instrument】

    NIR-1000 dry fluoroimmunoassay analyser produced by WWHS Biotech. Inc.


    Sample Requirements】

    1. Plasma, serum and whole blood can be used as samples. The whole blood should be collected in a tube containing citrate as the anticoagulant. If the serum procedure is used, collect blood in a tube without anticoagulant and allow clotting. Hemolyzed samples should not be used.
    2. Venous blood was collected according to routine laboratory methods to avoid hemolysis.
    3. It is highly recommended to use fresh samples instead of keeping the samples at room temperature for a long time. After samples were collected, the detection should be completed within 4 hours at room temperature (15℃~30℃). The whole blood sample can be stored at 2℃~8℃ for 48 hours. Plasma and serum samples can be stored at 2℃~ 8℃ for 7 days, -20℃for 30 days.
    4. Before testing, the sample should return to room temperature (15℃~30℃). The frozen samples should be completely thawed, rewarming and mixed evenly before use. Repeated freeze-thaw cycles should be avoided.

    Test procedure】

    1. Before the test, please read the instructions completely. If the test card and sample are stored in cold storage, they should be balanced at room temperature (15-30)℃ for not less than 30min before use.
    2. Start NIR-1000 dry fluoroimmunoassay analyser and correctly select the corresponding sample type on the instrument.
    3. Take out the ID card, make sure that the batch number of the ID card is consistent with that of the test card, and insert the ID card into the ID card port of the instrument.
    4. Take out the test card from the aluminum foil bag and use it within 15 minutes.
    5. Place the test card on a clean horizontal table and mark it horizontally.
    6. Mix 100 µL of urine sample with 200µL of sample diluent. Apply 100 µL of diluted samples to the well of the test card.
    7. Insert the test card into NIR-1000 dry fluoroimmunoassay analyser and click the “instant test” button to read the results at 10 minutes after addition of samples.

    Reference interval】

    S100β normal reference value is less than 0.20ng/mL. It is strongly recommended that each laboratory should determine its own normal and abnormal values.


    Performance】

    1. Limits of detection

    No higher than 0.05ng/mL

    2. Accuracy

    The relative deviation to the target value is limited to ±15.0%.

    1. Precision

    The within and between assay coefficient of variations are within 15%.

    1. Linear range

    Within the linear range [0.05,10.00]ng/mL, the linear correlation coefficient R≥0.990.


    【Note】

    1. The kit can be used for in vitro diagnosis only.

    2. Test card and buffer solution are single-use and they cannot be reused.

    3. Please check the integrity and validity of the kit package before use, and then open the package. When it is stored at low temperature, it should be restored to room temperature (15℃ ~ 30℃) before opening the package for use. The reagents with damaged inner package and beyond the validity period cannot be used.

    4. Take the test card out of the aluminum foil bag and carry out experiment in 15min. Do not place it in the air for a long time to avoid dampness.

    5. It is required to strictly comply with the requirements for sample collection and storage. If the sample is turbid, please centrifuge and precipitate it before use.

    6. The kit used should be disposed of as latent infective material, and all samples, reagents and latent contaminants should be disinfected and disposed of according to relevant local regulations.


    WWHS POCT Assay List


    Cardiac     
    cat#.Product itemSpecimenReaction TimeMeasure RangeClinical RangeItended Use
    1cTnIWB/Serum/Plasma12min.0.1-40ng/ml<0.3ng/mlseveral heart diseases including myocardial infarction and heart failure.
    2MyoWB/Serum/Plasma12min.5-400ng/ml<58ng/mlacute myocardial infarction (AMI) in early stage.
    3CK-MBWB/Serum/Plasma12min.1-200ng/ml<5ng/mlacute myocardial infarction (AMI) in early stage.
    4NT-proBNPWB/Serum/Plasma10min.20-35000pg/mlUnder 75:0~347pg/mL,
    Over 75:0~449pg/mL
    heart failure .
    5D-DimerWB/Plasma10min.40-10000ng/ml<500ng/mldisseminated intravascular coagulation (DIC),deep vein thrombosis (DVT),pulmonary embolism (PE), myocardial infarction, cerebral infarction, etc.
    6cTnI+Myo+CKMBWB/Serum/Plasma12min.same with single itemsame with single itemTriple marker of myocardial infarction.
    7ST2WB/Serum/Plasma10min.10-400ng/ml<35ng/mlheart failure .
    8Lp-PLA2WB/Serum/Plasma10min.10-900ng/ml<175ng/mlRisk evaluation of ACS and atherosclerotic ischemic stroke patients.
    9S100-βWB/Serum/Plasma10min.0.05-10ng/ml<0.2ng/mlCerebral infarction, cerebral injury.
    Inflammation     
    10CRP / hs-CRPWB/Serum/Plasma3min.0.5-200mg/LCRP<10mg/L,hs-CRP<1mg/Lnonspecficity inflammatory marker.
    11SAASerum5min.1-200mg/L<10mg/Linflammation&infection.
    12PCTWB/Serum/Plasma10min.0.2-100ng/ml<0.5ng/mlSepsis
    13CRP+SAAWB/Serum/Plasma5min.same with single itemsame with single iteminflammation&infection.
    14IL-6WB/Serum/Plasma10min.5-4000pg/ml10pg/mldiabetes,rheumatoid arthritis,etc
    Thyroid Hormone     
    15TSHSerum/Plasma15min.0.3-100mU/L0.35-5mU/Lhyperthyroidism and hypothyroidism
    16T3Serum/Plasma15min.0.5-10nmol/L1.3-3.1nmol/Lthyroid dysfunction
    17T4Serum/Plasma15min.5-300nmol/L66-181nmol/Lthyroid dysfunction
    Tumor Marker     
    18AFPSerum/Plasma15min.2.5-200ng/ml<20ng/mlpregnancy cancer
    19CEASerum/Plasma15min.1-200ng/ml<5ng/mlcolon cancer, colorectal cancer,etc.
    20NSESerum/Plasma15min.1-400ng/ml<16ng/mlnon-small cell lung cancer
    21FOBfecal specimens10min.50-1000ng/ml<100ng/mlAbnormal recessive gastrointestinal bleeding
    22PG IISerum/Plasma15min.1-100ug/LPGI/PGII>3.0gastric abnormalities
    23PG ISerum/Plasma15min.2.5-200ug/L>70ng/mlgastric abnormalities
    24PSASerum/Plasma15min.0.5-40ng/ml<4ng/mlprostate cancer
    25FPSASerum/Plasma15min.0.1-10ng/ml<1ng/mlprostate cancer
    26CA12-5Serum/Plasma15min.20-500U/ml<35U/mlovarian cancer
    27CA15-3Serum/Plasma15min.10-400U/ml< 25 U/mLbreast cancer
    28HE4Serum/Plasma15min.50-2000pmol/L<140 pmol/Lovarian cancer
    29CA19-9Serum/Plasma15min.10-400U/ml< 27 U/mLpancreatic cancer
    30β-HCGSerum/Plasma15min.5-400mIU/ml<10 mIU/mLEarly pregrancy, ectopic HCG cancer,incomplete abortion
    31CK19(Cyfra21-1)Serum/Plasma15min.0.5-50ng/ml<2.5ng/mlnon-small cell lung cancer

    High Accuracy S100-β Rapid Quantitative Test Kit FIA POCT Assay High Sensitivity


    Quality High Accuracy S100-β Rapid Quantitative Test Kit FIA POCT Assay High Sensitivity for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: WWHS Biotech.Inc(exclusive marketed by Dawin)
    *Subject:
    *Message:
    Characters Remaining: (0/3000)