Sign In | Join Free | My himfr.com
Home > POCT Instrument >

cTnI Cardiac Detection POCT Instrument 740nm Dry Fluorescence Immunoassay Analyzer

WWHS Biotech.Inc(exclusive marketed by Dawin)
Contact Now
    Buy cheap cTnI Cardiac Detection POCT Instrument 740nm Dry Fluorescence Immunoassay Analyzer from wholesalers
     
    Buy cheap cTnI Cardiac Detection POCT Instrument 740nm Dry Fluorescence Immunoassay Analyzer from wholesalers
    • Buy cheap cTnI Cardiac Detection POCT Instrument 740nm Dry Fluorescence Immunoassay Analyzer from wholesalers
    • Buy cheap cTnI Cardiac Detection POCT Instrument 740nm Dry Fluorescence Immunoassay Analyzer from wholesalers
    • Buy cheap cTnI Cardiac Detection POCT Instrument 740nm Dry Fluorescence Immunoassay Analyzer from wholesalers
    • Buy cheap cTnI Cardiac Detection POCT Instrument 740nm Dry Fluorescence Immunoassay Analyzer from wholesalers
    • Buy cheap cTnI Cardiac Detection POCT Instrument 740nm Dry Fluorescence Immunoassay Analyzer from wholesalers

    cTnI Cardiac Detection POCT Instrument 740nm Dry Fluorescence Immunoassay Analyzer

    Ask Lasest Price
    Brand Name : WWHS
    Model Number : NIR--1000
    Certification : ISO 13485, CE
    Price : Negotiable
    Payment Terms : T/T, L/C
    Supply Ability : 60 Sets per Day
    Delivery Time : 10 Days
    • Product Details
    • Company Profile

    cTnI Cardiac Detection POCT Instrument 740nm Dry Fluorescence Immunoassay Analyzer

    WWHS NIR-1000 Dry Fluorescent Immunoassay Analyser For cTnI Cardiac Detection


    The cTnI (Cardiac troponin I) Rapid Quantitative Test along with WWHS Fluorescence Immunoassay Analyzer is intended for vitro quantitative determination of Cardiac troponin I (cTnI) in human whole blood, serum or plasma. It is mainly used for auxiliary diagnosis of myocardial infarction.


    Description of WWHS NIR-1000 Dry Fluoroimmunoassay Analyser

    High Accuracy

    When the instrument tests the calibrated fluorescence test card, the deviation between the measured fluorescence value and the calibration value of the fluorescence test card is ±3.0%.

    Repeatability

    The variable coefficient of fluorescence value of fluorescence test cards of different intensities repeatedly measured by the instrument CV≤2.0%


    cTnI Cardiac Detection POCT Instrument 740nm Dry Fluorescence Immunoassay Analyzer


    WWHS Assay List


    Cardiac     
    cat#.Product itemSpecimenReaction TimeMeasure RangeClinical RangeItended Use
    1cTnIWB/Serum/Plasma12min.0.1-40ng/ml<0.3ng/mlseveral heart diseases including myocardial infarction and heart failure.
    2MyoWB/Serum/Plasma12min.5-400ng/ml<58ng/mlacute myocardial infarction (AMI) in early stage.
    3CK-MBWB/Serum/Plasma12min.1-200ng/ml<5ng/mlacute myocardial infarction (AMI) in early stage.
    4NT-proBNPWB/Serum/Plasma10min.20-35000pg/mlUnder 75:0~347pg/mL,
    Over 75:0~449pg/mL
    heart failure .
    5D-DimerWB/Plasma10min.40-10000ng/ml<500ng/mldisseminated intravascular coagulation (DIC),deep vein thrombosis (DVT),pulmonary embolism (PE), myocardial infarction, cerebral infarction, etc.
    6cTnI+Myo+CKMBWB/Serum/Plasma12min.same with single itemsame with single itemTriple marker of myocardial infarction.
    7ST2WB/Serum/Plasma10min.10-400ng/ml<35ng/mlheart failure .
    8Lp-PLA2WB/Serum/Plasma10min.10-900ng/ml<175ng/mlRisk evaluation of ACS and atherosclerotic ischemic stroke patients.
    9S100-βWB/Serum/Plasma10min.0.05-10ng/ml<0.2ng/mlCerebral infarction, cerebral injury.
    Inflammation     
    10CRP / hs-CRPWB/Serum/Plasma3min.0.5-200mg/LCRP<10mg/L,hs-CRP<1mg/Lnonspecficity inflammatory marker.
    11SAASerum5min.1-200mg/L<10mg/Linflammation&infection.
    12PCTWB/Serum/Plasma10min.0.2-100ng/ml<0.5ng/mlSepsis
    13CRP+SAAWB/Serum/Plasma5min.same with single itemsame with single iteminflammation&infection.
    14IL-6WB/Serum/Plasma10min.5-4000pg/ml10pg/mldiabetes,rheumatoid arthritis,etc
    Thyroid Hormone     
    15TSHSerum/Plasma15min.0.3-100mU/L0.35-5mU/Lhyperthyroidism and hypothyroidism
    16TT3Serum/Plasma15min.0.5-10nmol/L1.3-3.1nmol/Lthyroid dysfunction
    17TT4Serum/Plasma15min.5-300nmol/L66-181nmol/Lthyroid dysfunction
    18FT3Serum/Plasma15min.1-100pmol/L4-10pmol/Lthyroid dysfunction
    19FT4Serum/Plasma15min.5-300pmol/L19-39pmol/Lthyroid dysfunction
    Tumor Marker     
    20AFPSerum/Plasma15min.2.5-200ng/ml<20ng/mlpregnancy cancer
    21CEASerum/Plasma15min.1-200ng/ml<5ng/mlcolon cancer, colorectal cancer,etc.
    22NSESerum/Plasma15min.1-400ng/ml<16ng/mlnon-small cell lung cancer
    23FOBfecal specimens10min.50-1000ng/ml<100ng/mlAbnormal recessive gastrointestinal bleeding
    24PG IISerum/Plasma15min.1-100ug/LPGI/PGII>3.0gastric abnormalities
    25PG ISerum/Plasma15min.2.5-200ug/L>70ng/mlgastric abnormalities
    26TPSASerum/Plasma15min.0.5-40ng/ml<4ng/mlprostate cancer
    27FPSASerum/Plasma15min.0.1-10ng/ml<1ng/mlprostate cancer
    28CA12-5Serum/Plasma15min.20-500U/ml<35U/mlovarian cancer
    29CA15-3Serum/Plasma15min.10-400U/ml< 25 U/mLbreast cancer
    30HE4Serum/Plasma15min.50-2000pmol/L<140 pmol/Lovarian cancer
    31CA19-9Serum/Plasma15min.10-400U/ml< 27 U/mLpancreatic cancer
    32β-HCGSerum/Plasma15min.5-400mIU/ml<10 mIU/mLEarly pregrancy, ectopic HCG cancer,incomplete abortion
    33CK19(Cyfra21-1)Serum/Plasma15min.0.5-50ng/ml<2.5ng/mlnon-small cell lung cancer
    Fertility     
    34HCG / β-HCGSerum/Plasma10min.5-20000mIU/ml<5 mIU/mLearly pregrancy.
    35AMHSerum/Plasma10min.0.1-16ng/mlMale: 20-60 years old, 0.92-13.89 ng/mL
    Female: 20-29 years old, 0.88-10.35 ng/mL
    30-39 years old, 0.31-7.86 ng/mL 40 -50 years old, <5. 07 ng/mL
    ovarian reserve level
    Gastrointestinal      
    36FOBfecal specimens10min.qualitativequalitativegastrointestinal hemorrhage.
    37TRFfecal specimens10min.qualitativequalitativegastrointestinal hemorrhage.
    38FOB+TRFfecal specimens10min.qualitativequalitativegastrointestinal hemorrhage.
    Infection      
    39C.PneumoniaWB/Serum/Plasma15min.qualitativequalitativeCP infection
    40M.PneumoniaWB/Serum/Plasma15min.qualitativequalitativeMP infection
    41Covid-19 Antigennasal swab, throat swab or nasal wash/aspirate specimens15min.qualitativequalitativerespiratory tract
    42Covid-19 Ab IgG/IgMWB/Serum/Plasma15min.qualitativequalitativerespiratory tract
    43FluAnasal swab, throat swab or nasal wash/aspirate specimens15min.qualitativequalitativerespiratory tract
    44FluBnasal swab, throat swab or nasal wash/aspirate specimens15min.qualitativequalitativerespiratory tract
    Renal Injury      
    45CysCWB/Serum/Plasma5min.0.4-9mg/L0.5-1.1mg/Lrenal function
    46NGALUrine10min.10-1500ng/mL<132ng/mLacute kidney injury.
    Other      
    47FERRSerum5min.10-500ng/mlMale:24ng/mL~335ng/mL,
    Female:11ng/mL~307ng/mL
    iron metabolism related diseases, such as hemochromatosis and iron deficiency anemia
    48HbA1cWB10min.4%-14%4%-6%diabetes
    49VDSerum/Plasma15min.8-70ng/mL19-57ng/mLfetation

    About NIR-1000 Dry Fluoroimmunoassay Analyser


    It is a fluorescence immunochromatographic analysing system with internal temperature

    control,

    which can help diagnose conditions such as infection, diabetes, cardiovascular diseases,

    renal injury and cancers, etc.

    Immunofluorescence technology

    Testing time less than 15 minutes

    Easy-to-use touch-screen platform,multi-language system

    Reagents stored at room temperature for 12 months


    Product Features


    1 Wide-Range Diagnostics, It can be used in following areas:

    1) Department of thoracic Surgery

    2) Clinical Laboratory

    3) Department of Emergency

    4) First Aid Community Hospital

    5) Department of Respiration

    6) CCU/ICU

    7) Department of cardiology

    8) Department of Geriatrics


    2 Simple Procedure To Operate

    1) Sample Can Be Plasma&whole Blood

    2) Choose Internal Or External According To Needs

    3) Single&Batch Processing

    only two simple steps: Add 100ul blood sample to the test strip and wait for 15 minutes, then insert the test strip into the device and get the results


    Quality cTnI Cardiac Detection POCT Instrument 740nm Dry Fluorescence Immunoassay Analyzer for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: WWHS Biotech.Inc(exclusive marketed by Dawin)
    *Subject:
    *Message:
    Characters Remaining: (0/3000)