Sign In | Join Free | My himfr.com
Home > Cardiac Testing Kit >

Lp-PLA2 Cardiac Testing Kit Assay Diagnostic High Sensitivity

WWHS Biotech.Inc(exclusive marketed by Dawin)
Contact Now
    Buy cheap Lp-PLA2 Cardiac Testing Kit Assay Diagnostic High Sensitivity from wholesalers
     
    Buy cheap Lp-PLA2 Cardiac Testing Kit Assay Diagnostic High Sensitivity from wholesalers
    • Buy cheap Lp-PLA2 Cardiac Testing Kit Assay Diagnostic High Sensitivity from wholesalers
    • Buy cheap Lp-PLA2 Cardiac Testing Kit Assay Diagnostic High Sensitivity from wholesalers
    • Buy cheap Lp-PLA2 Cardiac Testing Kit Assay Diagnostic High Sensitivity from wholesalers

    Lp-PLA2 Cardiac Testing Kit Assay Diagnostic High Sensitivity

    Ask Lasest Price
    Brand Name : WWHS
    Model Number : Lp-PLA2
    Certification : CE
    Price : Negotiable
    Payment Terms : T/T
    Supply Ability : 50000 Kits per Week
    Delivery Time : 7 Days
    • Product Details
    • Company Profile

    Lp-PLA2 Cardiac Testing Kit Assay Diagnostic High Sensitivity

    【Product name】

    Diagnostic Kit for Lipoprotein-Associated Phospholipase A2(Immunochromatographic assay)


    【Package specification】

    25 Tests/kit


    【Intended use】

    This kit is used for quantitative determination of Lp-PLA2 in human whole blood, plasma and serum.

    Clinically, it is mainly used to evaluate the degree of atherosclerosis inflammation and the auxiliary diagnosis of cardiovascular and cerebrovascular diseases caused by atherosclerosis.


    【Test principle】

    The Lp-PLA2 Rapid Test is a one-step chromatographic sandwich immunoassay designed for the quantitative measurement of Lp-PLA2. The Lp-PLA2 antigen in the sample was first bound with the conjugated compound of fluorescent labeled Lp-PLA2 monoclonal antibody, then moved and combined with another Lp-PLA2 monoclonal antibody fixed on the nitrocellulose membrane, and the double antibody sandwich complex was formed at the detection line of the cellulose nitrate membrane. The quantitative detection results were obtained by NIR-1000 dry fluoroimmunoassay analyser.


    【Components】

    NameQuantityComponent
    Test cards25It is composed of fluorescent pad (coated with fluorescent labeled Lp-PLA2 monoclonal antibody), nitrocellulose membrane (coated with Lp-PLA2 monoclonal antibody and Goat anti mouse IgG antibody), absorbent paper and backing
    Sample diluent25(600μL/tube)Phosphate buffer
    ID card1With specific stand curve file

    The components in different batches of kits cannot be used interchangeably.


    【Storage conditions and validity】

    The kit should be stored at 4℃~30℃, out of direct sunlight. It is valid for 18 months. The test card should be used within 15 minutes after unsealing under the environment of 15℃~30℃ and 20% ~ 90% relative humidity.

    The production date, batch number and expiration date are shown in the outer package of the product.


    【Applicable instruments】

    NIR-1000 dry fluoroimmunoassay analyser produced by WWHS Biotech. Inc


    【Sample requirements】

    1. Plasma, serum and whole blood can be used as samples. The whole blood should be collected in a tube containing heparin, citrate or EDTA as the anticoagulant. If the serum procedure is used, collect blood in a tube without anticoagulant and allow clotting. Hemolyzed samples should not be used.
    2. Venous blood was collected according to routine laboratory methods to avoid hemolysis.
    3. It is highly recommended to use fresh samples instead of keeping the samples at room temperature for a long time. After samples were collected, the detection should be completed within 4 hours at room temperature (15℃~30℃). The whole blood sample can be stored at 2℃~8℃ for 24 hours. Plasma and serum samples can be stored at 2℃~ 8℃ for 7 days, -20℃for 30 days.
    4. Before testing, the sample should return to room temperature (15℃~30℃). The frozen samples should be completely thawed, rewarming and mixed evenly before use. Repeated freeze-thaw cycles should be avoided.

    【Test procedure】

    1. Before the test, please read the instructions completely. If the test card and sample are stored in cold storage, they should be balanced at room temperature (15-30)℃ for not less than 30min before use.
    2. Start NIR-1000 dry fluoroimmunoassay analyser and correctly select the corresponding sample type on the instrument.
    3. Take out the ID card, make sure that the batch number of the ID card is consistent with that of the test card, and insert the ID card into the ID card port of the instrument.
    4. Take out the test card from the aluminum foil bag and use it within 15 minutes.
    5. Place the test card on a clean horizontal table and mark it horizontally.
    6. Mix 10 µL of sample with 600µL of sample diluent. Apply 100 µL of diluted samples to the well of the test card.
    7. At 10 minutes after addition of samples, insert the test card into NIR-1000 dry fluoroimmunoassay analyser and click the “Instant test” button to read the results.

    【Reference interval】

    Healthy non-pregnant adults are expected to have serum Lp-PLA2 values below 175.00ng/mL. It is strongly recommended that each laboratory should determine its own normal and abnormal values based on population.


    【Interpretation of results】

    1. This reagent is only used for auxiliary detection. If the test results are abnormal, it should be reviewed in time and judged in combination with clinical symptoms.
    2. For samples with Lp-PLA2 concentration lower than 10.00ng/mL and higher than 900.00ng/mL, the detection results are reported as "<10.00ng/mL" and "> 900.00ng/mL", respectively.

    【Limitations of methods】

    1. This kit is only used to detect human plasma/whole blood samples
    2. Due to the limitations of immunoassay methods of antigen and antibody reaction, the results cannot be used as the only basis for clinical diagnosis, but should be evaluated with all the existing clinical and experimental data.
    3. The content of triglyceride in the sample shall not exceed 15mg/ml, the content of hemoglobin shall not exceed 5mg/ml, and the content of bilirubin shall not exceed 0.5mg/ml, and the relative deviation of the test results shall not exceed ±15%.
    4. When the concentration of Lp-PLA2 in the sample is less than 1800ng/mL, there is no hook effect.
    5. HAMA effect was not produced when the concentration of human anti rat in the sample was less than 50ng/ml.
    6. When RF concentration in the sample is less than 2000IU/ml, the relative deviation of the test results is within ±15%.

    【Performance】

    1. Limits of detection

    No more than 10.00ng/mL.

    2. Accuracy

    The relative deviation from the target value is within ±15%.

    3. Precision

    The within and between assay coefficient of variations are within 15%.

    4. Linear range

    Within the linear range (10.00~ 900.00ng/mL), the linear correlation coefficient R≥0.990.


    【Note】

    1. This kit is only used for in vitro diagnosis.

    2. The test card and sample diluent are disposable and cannot be reused.

    3. Please check the integrity and validity of the kit package before use, and then open the package. When it is stored at low temperature, it should be restored to room temperature (15℃ ~ 30℃) before opening the package for use. The reagents with damaged inner package and beyond the validity period cannot be used.

    4. The requirements of specimen collection and storage should be strictly observed. If the specimen is turbid, it should be centrifuged and discarded before use.

    5. The used kits should be treated as potential infectious substances, and all samples, reagents and potential pollutants should be disinfected and treated according to the relevant local regulations.



    Assay list     
    Cardiac     
    cat#.Product ItemSpecimenReaction TimeMeasure RangeClinical RangeIntended Use
    1cTnIWB/Serum/Plasma12min.0.1-40ng/ml<0.3ng/mlseveral heart diseases including myocardial infarction and heart failure.
    2MyoWB/Serum/Plasma12min.5-400ng/ml<58ng/mlacute myocardial infarction (AMI) in early stage.
    3CK-MBWB/Serum/Plasma12min.1-200ng/ml<5ng/mlacute myocardial infarction (AMI) in early stage.
    4NT-proBNPWB/Serum/Plasma10min.20-35000pg/mlUnder 75:0~347pg/mL,
    Over 75:0~449pg/mL
    heart failure .
    5D-DimerWB/Plasma10min.40-10000ng/ml<500ng/mldisseminated intravascular coagulation (DIC),deep vein thrombosis (DVT),pulmonary embolism (PE), myocardial infarction, cerebral infarction, etc.
    6cTnI+Myo+CKMBWB/Serum/Plasma12min.same with single itemsame with single itemTriple marker of myocardial infarction.
    7ST2WB/Serum/Plasma10min.10-400ng/ml<35ng/mlheart failure .
    8Lp-PLA2WB/Serum/Plasma10min.10-900ng/ml<175ng/mlRisk evaluation of ACS and atherosclerotic ischemic stroke patients.
    9S100-βWB/Serum/Plasma10min.0.05-10ng/ml<0.2ng/mlCerebral infarction, cerebral injury.


    About NIR-1000 Dry Fluoroimmunoassay Analyser


    It is a fluorescence immunochromatographic analysing system with internal temperature control,

    which can help diagnose conditions such as infection, diabetes, cardiovascular diseases, renal injury and cancers, etc.

    Immunofluorescence technology

    Testing time less than 15 minutes

    Easy-to-use touch-screen platform,multi-language system

    Reagents stored at room temperature for 12 months

    Dry immune technology, maintenance free


    FAQ:


    1. What is the MOQ?


    Generally if you choose the different products, our minimum order qty. also will be different. One sample available.


    2. What about the delivery time?


    The goods need 7-21 work days to be made upon deposit.


    3. Does your product have any warranty?


    Yes, we offer 6 months limited warranty for our products.


    Damage due to misuse, ill treatment and unauthorized modifications and repairs are not covered by our warranty.


    4. What's your payment method?


    We usually accept the payment methods include PayPal, TT, and Western Union.


    50% deposit in advance and balance before shipping. Buyer can choose which payment ways that you accept.


    PayPal is most useful and safe, please don’t refuse PayPal fee when you choose PayPal.


    5. What's your shipping method?


    We provide comprehensive shipping methods.


    For small quantity orders we ship by DHL Air-Express, or EMS/TNT/UPS/FEDEX Express service, it is safe and fast.


    For large quantity orders we ship by Air transportation or sea transportation, we can also ship order to buyer’s cargo agent in China.

    Quality Lp-PLA2 Cardiac Testing Kit Assay Diagnostic High Sensitivity for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: WWHS Biotech.Inc(exclusive marketed by Dawin)
    *Subject:
    *Message:
    Characters Remaining: (0/3000)