Sign In | Join Free | My himfr.com
Home > POCT Test Kit >

PGII High Accuracy Tumor Marker Rapid Test Kit WWHS FIA POCT Assay 25T

WWHS Biotech.Inc(exclusive marketed by Dawin)
Contact Now
    Buy cheap PGII High Accuracy Tumor Marker Rapid Test Kit WWHS FIA POCT Assay 25T from wholesalers
     
    Buy cheap PGII High Accuracy Tumor Marker Rapid Test Kit WWHS FIA POCT Assay 25T from wholesalers
    • Buy cheap PGII High Accuracy Tumor Marker Rapid Test Kit WWHS FIA POCT Assay 25T from wholesalers
    • Buy cheap PGII High Accuracy Tumor Marker Rapid Test Kit WWHS FIA POCT Assay 25T from wholesalers
    • Buy cheap PGII High Accuracy Tumor Marker Rapid Test Kit WWHS FIA POCT Assay 25T from wholesalers

    PGII High Accuracy Tumor Marker Rapid Test Kit WWHS FIA POCT Assay 25T

    Ask Lasest Price
    Brand Name : WWHS
    Model Number : PG-II
    Certification : ISO 13485, CE
    Price : Negotiable
    Payment Terms : L/C, T/T
    Supply Ability : 50000 Kits per Week
    Delivery Time : 7 Days
    • Product Details
    • Company Profile

    PGII High Accuracy Tumor Marker Rapid Test Kit WWHS FIA POCT Assay 25T

    PGII High Accuracy Tumor Marker Rapid Test Kit WWHS FIA POCT Assay 25T


    PGI/PGII Rapid Quantitative Test Human pepsinogens I (PGI) and II (PGII) are proenzymes of pepsin—an

    endoproteinase of gastric juice. PGI is secreted mainly by chief cells in the fundic mucosa, whereas

    PGII is also secreted by the pyloric glands and the proximal duodenal mucosa.


    NameLoading CapacityComponent
    Test Card25 PersonsThe product consists of fluorescent mat (coated with fluorescently-labeled PGII antibody), nitrocellulose membrane (coated with PGII antibody), absorbent paper and PVC soleplate, and so on.
    Sample Buffer25 vials (0.3mL/vial)Phosphate buffer
    Information Card1 PieceRecord standard curve information of this batch of reagents

    WWHS Assay Items


    Tumor Marker     
    cat#.Product ItemSpecimenReaction TimeMeasure RangeClinical RangeIntended Use
    20AFPSerum/Plasma15min.2.5-200ng/ml<20ng/mlpregnancy cancer
    21CEASerum/Plasma15min.1-200ng/ml<5ng/mlcolon cancer, colorectal cancer,etc.
    22NSESerum/Plasma15min.1-400ng/ml<16ng/mlnon-small cell lung cancer
    23FOBfecal specimens10min.50-1000ng/ml<100ng/mlAbnormal recessive gastrointestinal bleeding
    24PG IISerum/Plasma15min.1-100ug/LPGI/PGII>3.0gastric abnormalities
    25PG ISerum/Plasma15min.2.5-200ug/L>70ng/mlgastric abnormalities
    26TPSASerum/Plasma15min.0.5-40ng/ml<4ng/mlprostate cancer
    27FPSASerum/Plasma15min.0.1-10ng/ml<1ng/mlprostate cancer
    28CA12-5Serum/Plasma15min.20-500U/ml<35U/mlovarian cancer
    29CA15-3Serum/Plasma15min.10-400U/ml< 25 U/mLbreast cancer
    30HE4Serum/Plasma15min.50-2000pmol/L<140 pmol/Lovarian cancer
    31CA19-9Serum/Plasma15min.10-400U/ml< 27 U/mLpancreatic cancer
    32β-HCGSerum/Plasma15min.5-400mIU/ml<10 mIU/mLEarly pregrancy, ectopic HCG cancer,incomplete abortion
    33CK19(Cyfra21-1)Serum/Plasma15min.0.5-50ng/ml<2.5ng/mlnon-small cell lung cancer

    PGII High Accuracy Tumor Marker Rapid Test Kit WWHS FIA POCT Assay 25T




    Quality Control


    A procedural control is included in the test. A colored line appearing in the control region (C) is the internal procedural
    control. It confirms sufficient specimen volume and correct procedural technique.
    Control standards are not supplied with this kit; however, it is recommended that a positive control and a negative control control be tested as a good laboratory practice to confirm the test procedure and to verify proper test performance.


    Test Method


    1. Please thoroughly read the specification before test. Frozen test card and sample should be placed at room temperature (15-30) ℃ for at least 30min before use.
    2. Start NIR-1000 dry fluoroimmunoassay analyser and verify quality control according to the specification.
    3. The quality of reagent is controlled using internal quality control product (not provided) of the company and result should be controllable.
    4. Take out the test card from the aluminum foil bag and use it within 15min
    5. Place the test card on a clean horizontal table top and label it.
    6. Take 10μL of sample and add it into HbA1c sample buffer (1.00mL). Then, mix the solution evenly, take 100μL of the solution and add it into the well.
    7. Insert the test card into NIR-1000 dry fluoroimmunoassay analyser, keep time for 10min and press 【Instant test】. The analyser will judge and read the test result automatically. Or press 【Fixed time test】 to keep time for 10min automatically. The analyser will judge and read the test result automatically and display it in the screen.


    Applicable Instrument


    WWHS NIR-1000 dry fluoroimmunoassay analyser

    Quality PGII High Accuracy Tumor Marker Rapid Test Kit WWHS FIA POCT Assay 25T for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: WWHS Biotech.Inc(exclusive marketed by Dawin)
    *Subject:
    *Message:
    Characters Remaining: (0/3000)