Sign In | Join Free | My himfr.com
Home > PCT Rapid Test Kit >

WWHS Procalcitonin Rapid Quantitative One Step Test Kit for Whole Blood

WWHS Biotech.Inc(exclusive marketed by Dawin)
Contact Now
    Buy cheap WWHS Procalcitonin Rapid Quantitative One Step Test Kit for Whole Blood from wholesalers
     
    Buy cheap WWHS Procalcitonin Rapid Quantitative One Step Test Kit for Whole Blood from wholesalers
    • Buy cheap WWHS Procalcitonin Rapid Quantitative One Step Test Kit for Whole Blood from wholesalers
    • Buy cheap WWHS Procalcitonin Rapid Quantitative One Step Test Kit for Whole Blood from wholesalers
    • Buy cheap WWHS Procalcitonin Rapid Quantitative One Step Test Kit for Whole Blood from wholesalers
    • Buy cheap WWHS Procalcitonin Rapid Quantitative One Step Test Kit for Whole Blood from wholesalers

    WWHS Procalcitonin Rapid Quantitative One Step Test Kit for Whole Blood

    Ask Lasest Price
    Brand Name : WWHS
    Model Number : PCT
    Certification : ISO 13485, CE
    Price : Negotiable
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 5000 Kits per Day
    Delivery Time : 7 Days
    • Product Details
    • Company Profile

    WWHS Procalcitonin Rapid Quantitative One Step Test Kit for Whole Blood

    [Product Name]

    Procalcitonin (PCT) Rapid Quantitative Test (Fluorescence immunoassay)

    [Packing Specification]

    25 Tests/kit

    [Intended Use]

    The product is used to determine the content of procalcitonin (PCT) in whole blood, plasma and serum of human body and is mainly used clinically for auxiliary diagnosis of bacterial infectious diseases.

    [Test Principle]

    The kit uses immunochromatographic assay. First, PCT antigen in the sample combines with the fluorescently-labeled PCT monoclonal antibody conjugate. Then, it continues to move and combines with another PCT monoclonal antibody fixed on the nitrocellulose membrane to form double-antibody sandwich immune complex in the position of the nitrocellulose membrane test line and analyze and obtain quantitative test result using NIR-1000 dry fluoroimmunoassay analyser.

    [Main Ingredients]

    NameLoading capacityIngredient
    Test card25The product consists of fluorescent mat (coated with fluorescently-labeled PCT monoclonal murine antibody), nitrocellulose membrane (coated with PCT monoclonal murine antibody and goat anti mouse IgG antibody), absorbent paper and bottom lining.
    Sample diluent25Phosphate buffer
    ID card1Record standard curve information of this batch of reagents

    Ingredients of kits of different batch numbers cannot be exchanged.

    [Storage Conditions and Validity]

    The product should be stored at 4℃-30℃ in a dry and dark place, sealed using aluminum foil bag and must not be frozen. The storage life is 12 months. The test card should be unpacked at room temprature (15℃-30℃) and should be used in 15min after unpacked at a temperature of (15-30)℃ and relative humidity of 20%-90%.

    See outer packing for production date, batch number and expiry date.

    [Applicable Instrument]

    NIR-1000 dry fluoroimmunoassay analyser produced by WWHS Biotech. Inc.

    [Sample Requirements]

    1. Serum and EDTA·Na2 anticoagulant plasma and whole blood, EDTA·K2 anticoagulant plasma and whole blood, sodium citrate anticoagulant plasma and whole blood can be used.
    2. Collect venous blood using coventional laboratory method. Clinical samples should be tested at room temperature (15℃-30℃) in 4h after collected. Whole blood specimens can be stored at (2-8)℃ for 24h; serum or plasma specimens can be stored at (2-8)℃ for 7 days and at -20ºC for 30 days.
    3. The sample must be rewarmed to room temperature (15-30)℃ before test. Frozen samples should be completely melted, rewarmed and mixed before use and should not be frozen repeatedly.
    4. Please do not test samples of severe hemolysis, severe lipoidemia and icterus.

    [Test Method]

    1. Please thoroughly read the specification before test. Frozen test card and sample should be placed at room temperature (15-30)℃ for at least 30min before use.
    2. Start NIR-1000 dry fluoroimmunoassay analyser and verify quality control according to the specification. (Note: Reagent has been calibrated in advance and calibration curve parameters of each batch of reagents have been stored in the information card. Insert the information card before use and carry out test without re-calibration after passing quality inspection; otherwise, identify the cause before test.)
    3. Take out the test card from the aluminum foil bag and use it within 15min
    4. Place the test card on a clean horizontal table top and label it.
    5. Take 100μL of sample and add it into 300μL of buffer solution (1:3). Then, mix the solution evenly, take 100μL of the solution and add it into the test card well.
    6. Insert the test card into NIR-1000 dry fluoroimmunoassay analyser and press “Timing test” to keep time for 10min automatically. The analyzer will judge and read the test result automatically and display it in the screen. Or insert the test card into the analyzer after 10min and press “Instant test”, the instrument will judge and read the result automatically.

    【Reference Interval】

    Determine 254 healthy people aged 18-68 and carry out statistical analysis. Result shows that the upper limit of the reference value is 0.5ng/mL at the 95th percentile, so the reference interval is less than 0.5ng/mL.

    The laboratory should establish a reference range according to characteristics of local people.

    [Interpretation of Test Results]

    1. The kit can be used for auxiliary test only. If test result is abnormal, retest timely and judge combined with clinical symptoms.

    2. For samples whose PCT concentration is lower than 0.2ng/mL and higher than 100ng/mL, test result is “<0.2ng/mL” and “>100ng/mL” respectively.

    [Limitation of Test Method]

    1. The kit can be used to test whole blood, plasma and serum specimens of human body only.

    2. Due to limitations of serological methods for antigen and antibody response, the test result cannot be used as the only basis for clinical diagnosis and should be evaluated together with all existing clinical and experimental data.

    1. The content of triglyceride contained in the sample is no more than 10mg/mL, that of hemoglobin is no more than 6mg/mL and that of hemoglobin is no more than 0.6mg/mL, and the relative deviation is limited to ±15%.
    2. When PCT concentration of samples is less than 250ng/mL, Hook effect is not observed.

    5. When human anti mouse concentration of samples is less than 50ng/mL, HAMA effect will not be observed.

    6. When RF concentration of samples is less than 2000 IU/mL, the test result will not be affected.

    [Product Performance Indicators]

    1. Limit of detection

    No more than 0.2ng/mL

    1. Accuracy

    The relative deviation to the target value is limited to ±15%.

    1. Precision

    Within-run precision CV≤15%; between-run relative limit R≤15%.

    1. Linearity range

    Within the specified linearity range (0.2-100) ng/mL, linearly dependent coefficient r≥0.990.

    【Precautions】

    1. Test card is single-use and it cannot be reused.
    2. Please inspect packaging integrity and validity of kit before use and then unpack the product. If the product is stored at low temperature, restore to room temperature (15℃-30℃) before unpacking and use. Reagent cannot be used if packaging is damaged and the validity period expires.
    3. Take the test card out of the aluminum foil bag and carry out experiment in 15min. Do not place it in the air for a long time to avoid dampness.
    4. It is required to strictly comply with the requirements for sample collection and storage. If the sample is turbid, please centrifuge and precipitate it before use.
    5. The kit contains products from animals. Eligible information about animal source and sanitary condition cannot absolutely ensure inexistence of infectious pathogen. Therefore, these products should be disposed of as latent infective material, and all samples, reagents and latent contaminants should be disinfected and disposed of according to relevant local regulations.
    6. Too high or too low hematocrit of red cells may affect whole blood test result, so verification should be conducted using other methods .


    Assay list     
    Cardiac     
    cat#.Product itemSpecimenReaction TimeMeasure RangeClinical RangeItended Use
    1cTnIWB/Serum/Plasma12min.0.1-40ng/ml<0.3ng/mlseveral heart diseases including myocardial infarction and heart failure.
    2MyoWB/Serum/Plasma12min.5-400ng/ml<58ng/mlacute myocardial infarction (AMI) in early stage.
    3CK-MBWB/Serum/Plasma12min.1-200ng/ml<5ng/mlacute myocardial infarction (AMI) in early stage.
    4NT-proBNPWB/Serum/Plasma10min.20-35000pg/mlUnder 75:0~347pg/mL,
    Over 75:0~449pg/mL
    heart failure .
    5D-DimerWB/Plasma10min.40-10000ng/ml<500ng/mldisseminated intravascular coagulation (DIC),deep vein thrombosis (DVT),pulmonary embolism (PE), myocardial infarction, cerebral infarction, etc.
    6cTnI+Myo+CKMBWB/Serum/Plasma12min.same with single itemsame with single itemTriple marker of myocardial infarction.
    7ST2WB/Serum/Plasma10min.10-400ng/ml<35ng/mlheart failure .
    8Lp-PLA2WB/Serum/Plasma10min.10-900ng/ml<175ng/mlRisk evaluation of ACS and atherosclerotic ischemic stroke patients.
    9S100-βWB/Serum/Plasma10min.0.05-10ng/ml<0.2ng/mlCerebral infarction, cerebral injury.
    Inflammation     
    10CRP / hs-CRPWB/Serum/Plasma3min.0.5-200mg/LCRP<10mg/L,hs-CRP<1mg/Lnonspecficity inflammatory marker.
    11SAASerum5min.1-200mg/L<10mg/Linflammation&infection.
    12PCTWB/Serum/Plasma10min.0.2-100ng/ml<0.5ng/mlSepsis
    13CRP+SAAWB/Serum/Plasma5min.same with single itemsame with single iteminflammation&infection.
    14IL-6WB/Serum/Plasma10min.5-4000pg/ml10pg/mldiabetes,rheumatoid arthritis,etc
    Thyroid Hormone     
    15TSHSerum/Plasma15min.0.3-100mU/L0.35-5mU/Lhyperthyroidism and hypothyroidism
    16TT3Serum/Plasma15min.0.5-10nmol/L1.3-3.1nmol/Lthyroid dysfunction
    17TT4Serum/Plasma15min.5-300nmol/L66-181nmol/Lthyroid dysfunction
    18FT3Serum/Plasma15min.1-100pmol/L4-10pmol/Lthyroid dysfunction
    19FT4Serum/Plasma15min.5-300pmol/L19-39pmol/Lthyroid dysfunction
    Tumor Maker     
    20AFPSerum/Plasma15min.2.5-200ng/ml<20ng/mlpregnancy cancer
    21CEASerum/Plasma15min.1-200ng/ml<5ng/mlcolon cancer, colorectal cancer,etc.
    22NSESerum/Plasma15min.1-400ng/ml<16ng/mlnon-small cell lung cancer
    23FOBfecal specimens10min.50-1000ng/ml<100ng/mlAbnormal recessive gastrointestinal bleeding
    24PG IISerum/Plasma15min.1-100ug/LPGI/PGII>3.0gastric abnormalities
    25PG ISerum/Plasma15min.2.5-200ug/L>70ng/mlgastric abnormalities
    26TPSASerum/Plasma15min.0.5-40ng/ml<4ng/mlprostate cancer
    27FPSASerum/Plasma15min.0.1-10ng/ml<1ng/mlprostate cancer
    28CA12-5Serum/Plasma15min.20-500U/ml<35U/mlovarian cancer
    29CA15-3Serum/Plasma15min.10-400U/ml< 25 U/mLbreast cancer
    30HE4Serum/Plasma15min.50-2000pmol/L<140 pmol/Lovarian cancer
    31CA19-9Serum/Plasma15min.10-400U/ml< 27 U/mLpancreatic cancer
    32β-HCGSerum/Plasma15min.5-400mIU/ml<10 mIU/mLEarly pregrancy, ectopic HCG cancer,incomplete abortion
    33CK19(Cyfra21-1)Serum/Plasma15min.0.5-50ng/ml<2.5ng/mlnon-small cell lung cancer
    Fertility     
    34HCG / β-HCGSerum/Plasma10min.5-20000mIU/ml<5 mIU/mLearly pregrancy.
    35AMHSerum/Plasma10min.0.1-16ng/mlMale: 20-60 years old, 0.92-13.89 ng/mL
    Female: 20-29 years old, 0.88-10.35 ng/mL
    30-39 years old, 0.31-7.86 ng/mL 40 -50 years old, <5. 07 ng/mL
    ovarian reserve level
    Gastrointestinal      
    36FOBfecal specimens10min.qualitativequalitativegastrointestinal hemorrhage.
    37TRFfecal specimens10min.qualitativequalitativegastrointestinal hemorrhage.
    38FOB+TRFfecal specimens10min.qualitativequalitativegastrointestinal hemorrhage.
    Infection      
    39C.PneumoniaWB/Serum/Plasma15min.qualitativequalitativeCP infection
    40M.PneumoniaWB/Serum/Plasma15min.qualitativequalitativeMP infection
    41Covid-19 Antigennasal swab, throat swab or nasal wash/aspirate specimens15min.qualitativequalitativerespiratory tract
    42Covid-19 Ab IgG/IgMWB/Serum/Plasma15min.qualitativequalitativerespiratory tract
    43FluAnasal swab, throat swab or nasal wash/aspirate specimens15min.qualitativequalitativerespiratory tract
    44FluBnasal swab, throat swab or nasal wash/aspirate specimens15min.qualitativequalitativerespiratory tract
    Renal Injury      
    45CysCWB/Serum/Plasma5min.0.4-9mg/L0.5-1.1mg/Lrenal function
    46NGALUrine10min.10-1500ng/mL<132ng/mLacute kidney injury.
    Other      
    47FERRSerum5min.10-500ng/mlMale:24ng/mL~335ng/mL,
    Female:11ng/mL~307ng/mL
    iron metabolism related diseases, such as hemochromatosis and iron deficiency anemia
    48HbA1cWB10min.4%-14%4%-6%diabetes
    49VDSerum/Plasma15min.8-70ng/mL19-57ng/mLfetation

    WWHS Procalcitonin Rapid Quantitative One Step Test Kit for Whole Blood


    Storage Conditions and Validity


    The product should be stored at 4℃-30℃ in a dry and dark place, sealed using aluminum foil bag and must not be frozen. The storage life is 12 months. The test card should be unpacked at room temprature (15℃-30℃) and should be used in 15min after unpacked at a temperature of (15-30)℃ and relative humidity of 20%-90%.
    See outer packing for production date, batch number and expiry date.

    Why Choose Us


    Our company's main business is INFRARED fluorescent POCT. The main application scenarios of POCT include emergency department, ICU, chest pain center and stroke center, operating room, and various departments of grade hospitals. Community health, outpatient and other primary medical institutions at all levels; Pharmacies, home use and other organizations and individuals targeted at end customers. POCT is characterized by its simplicity and speed, freedom from application scenarios, and high cost performance. However, the current pain point of POCT industry lies in how to solve the problems of low sensitivity and poor precision faced by POCT products.


    1. Precision
    Deviation is less than 3.0%
    2. Upgraded data storage
    10000 data storage
    3. Long life
    Support to use 3 years


    FAQ:


    1. What is the MOQ?


    Generally if you choose the different products, our minimum order qty. also will be different. One sample available.


    2. What about the delivery time?


    The goods need 7-21 work days to be made upon deposit.


    3. Does your product have any warranty?


    Yes, we offer 6 months limited warranty for our products.


    Damage due to misuse, ill treatment and unauthorized modifications and repairs are not covered by our warranty.


    4. What's your payment method?


    We usually accept the payment methods include PayPal, TT, and Western Union.


    50% deposit in advance and balance before shipping. Buyer can choose which payment ways that you accept.


    PayPal is most useful and safe, please don’t refuse PayPal fee when you choose PayPal.


    5. What's your shipping method?


    We provide comprehensive shipping methods.


    For small quantity orders we ship by DHL Air-Express, or EMS/TNT/UPS/FEDEX Express service, it is safe and fast.


    For large quantity orders we ship by Air transportation or sea transportation, we can also ship order to buyer’s cargo agent in China.


    Applicable Instrument


    NIR-1000 dry fluoroimmunoassay analyser produced by Shenzhen WWHS Biotechnology Co., Ltd.


    Quality WWHS Procalcitonin Rapid Quantitative One Step Test Kit for Whole Blood for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: WWHS Biotech.Inc(exclusive marketed by Dawin)
    *Subject:
    *Message:
    Characters Remaining: (0/3000)